SCMOS Layout Rules - Via3

These are generic design rules. For TSMC02d, you need to use the rule numbers in the DEEP column and multiply the values by λ=0.09μm. Also, use 5+ Metal process rules.


Vias must be drawn orthogonal to the grid of the layout. Non-Manhattan vias are not allowed.

Rule Description Lambda
4 metal Process 5+ Metal Process
SCMOS SUBM DEEP SCMOS SUBM DEEP
21.1 Exact size 2x2 2x2 n/a n/a 2x2 3x3
21.2 Minimum spacing 3 3 * n/a n/a 3 3
21.3 Minimum overlap by Metal3 1 1 n/a n/a 1 1


SCMOS Layout Rules - Metal4


 

These are generic design rules. For TSMC02d, you need to use the rule numbers in the DEEP column and multiply the values by λ=0.09μm. Also, use 5+ Metal process rules.

Rule Description Lambda
4 Metal Process 5+ Metal Process
SCMOS SUBM DEEP SCMOS SUBM DEEP
22.1 METAL4 width 6 6 n/a n/a 3 3
22.2 METAL4 space 6 6 n/a n/a 3 4
22.3 METAL4 overlap of VIA3 2 2 n/a n/a 1 1
22.4 Minimum spacing when either metal line is wider than 10 lambda 12 12 n/a n/a 6 8